Manual of Quantitative Detection Kit (ELISA) for Human Soluble Vascular Cell Adhesion Factor 1 (sVCAM-1)

Human soluble vascular cell adhesion factor 1 (sVCAM-1) quantitative detection kit (ELISA)

user's Guide

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit kit name]

Human soluble vascular cell adhesion factor 1 (sVCAM-1) quantitative detection kit (ELISA)

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit kit uses]

Quantitative detection of soluble vascular cell adhesion factor 1 (sVCAM-1) in human serum, plasma and related fluid samples.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit detection principle]

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated human soluble vascular cell adhesion factor 1 (sVCAM-1) monoclonal antibody transparent enzyme label coated plate, after incubation for a sufficient time, wash to remove unbound components, and then Add enzyme-labeled working solution, and after incubation for a sufficient time, wash to remove unbound components. Substrates A and B are added in sequence, and the substrate (TMB) is converted into a blue product catalyzed by horseradish peroxidase (HRP) and turns yellow under the action of acid. The shade of the color and the soluble human vascular cells in the sample The concentration of adhesion factor 1 (sVCAM-1) was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of human soluble vascular cell adhesion factor 1 (sVCAM-1) in the sample was calculated.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit composition]

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 480, 240, 120, 60, 30, 15 μg / L

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit required but not provided reagents and equipment]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

[Operation steps of human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit]

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of sample to be tested, and then add 40μL of sample diluent (that is, the sample is diluted 5 times); blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with the washing solution, let stand for 1min, shake off the washing solution, pat dry on the absorbent paper, repeat the washing 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution, mix for 30s with a plate mixer (or gently shake for 30s by hand), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow).

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit sample requirements]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit notes]

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 15-480μg / L. If it exceeds this range, it is calculated by the extension of the standard curve. ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit operating procedures summary]

Prepare reagents, samples and standards


Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit detection range]

15μg / L-480μg / L

[Specification of Human Soluble Vascular Cell Adhesion Factor 1 (sVCAM-1) Elisa Kit]

96 servings / box

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit storage]

Store at 2-8 ℃, protected from light and moisture.

[Human soluble vascular cell adhesion factor 1 (sVCAM-1) Elisa kit expiration date]

6 months

Green House

  • Sturdy Structure: The cold frame greenhouse is made of fir wood which is durable and sturdy, offers long-term reliable use. And the polish and cutting workmanship on this outdoor greenhouse is smooth, allowing painting and staining on it without any other process.
  • Adjustable Shelf: The shelf of this mini greenhouse could be freely adjusted height to fit various types of plants, which meets all your needs. (Five screw holes preset, you can also make holes by yourself to determine the height of the shelf).
  • Efficient Protection: Garden greenhouse used transparent polycarbonate panels, which have maximum light transmission function while retaining heat for early seed sprouting and for protecting plants late in the season, your plants could enjoy the sun and grow healthily.
  • Openable Roof: The Bolt on the side could be used to fix the top keep open, and the size of the vents can be controlled by holding the screws in different rods position, providing a healthy ventilation system to your plants in different weather.
  • Convenient Installation: This greenhouse kit is included clear instructions, it's very easy to follow. Every part is clearly labeled, all tools you need are also included. If you need any help in installation, please feel free to contact us.

Green House,Garden Greenhouse For Plants,Outdoor Greenhouse For Plants,Greenhouse Hydroponic Plants

HANGZHOU JIEYUN IMP & EXP CO., LTD , https://www.jaalex-garden.com