Basic data of RAVEN incubator:
Model Voltage Power Current Frequency
I-120VAR (adjustable incubator) 120 52 0.42 50/60
I-240 (pre-adjusted incubator) 240 52 0.22 50/60
Operating range: room temperature to 70 ℃
Temperature stability: +/- 2 ℃
Pre-adjusted incubator: The incubator is preset to indicate the temperature before leaving the factory, but because the incubator experiences different climates during shipping, it may require a slight calibration.
If calibration is required, remove the rubber plug and insert a screwdriver into the thermostat in the tank. Turning it clockwise increases the temperature, and turning it counterclockwise decreases the temperature. It takes about 10 minutes to adjust to stable temperature, and adjust slowly until the desired temperature is reached and stabilized.
Instructions:
Turn on the power switch "ON".
For the pre-adjusted incubator, in order to ensure that the pre-adjusted temperature does not change during shipping or climatic environment, the temperature monitoring indicator bar is located on the plastic rack under the aluminum block.
For adjustable incubators, turn the temperature control disc clockwise. When the temperature indicator reaches the required temperature, turn the temperature control disc counterclockwise until the yellow light goes out. It takes about 10 minutes to stabilize the temperature. Adjust slowly until the required temperature is reached and stabilized.
note:
Do not place flammable or combustible materials near this instrument, as it may cause an explosion or fire.
Do not add water or soak in the instrument.
1. For best results, the test tube or self-contained biological indicator should be used with a plastic holder matching the size.
2. The instrument can not be placed in the outside too hot or too cold, it will affect its performance.
clean:
The instrument can be wiped with a slightly damp cloth. The aluminum block can be taken out and cleaned, and should be completely dry before being returned to the instrument.
accident:
If a solution splashes into the instrument, turn off the power and invert the instrument to prevent the solution from contacting the internal parts. Unscrew the 6 screws and check the parts to make sure that the solution does not touch the internal parts. (Replace damaged parts). It must be completely dry before connecting to the power supply.
Warning: Disconnect the power supply during maintenance.
From: http: //
Salon Chair
Used low noise and long lifetime moto. Precision mechanical welding iron fram, more stable
Used wear-resistant, very strong inpact-resistant ABS material shell to ensure high and quality from inside to outside
Selection of high-end and wear-resistant leather.
One touch easy operated handset
Armrest can be rotated 180 degree by hand
Extendable footrest with flexible adjustment
With CE&RoHs certificate
No MOQ, FOB prcie, Door to Door service